FEATURES |
|
|
|
|
|
|
The CE-0027A 8 channel RS422 splitter unit provides 8 RS422 data and clock signal outputs from either a RS232 or RS422 processed radar data and clock signal input based on the RS530 standard according to a DTE device.
The input data and clock signals may be monitored at the front panel RS232 DB25F connector.
Two input connectors, each a DB25M are available at the rear of the unit for connecting RS232 or RS422 processed radar data and clock signals according to a DTE device respectively.
(ONLY ONE INPUT CAN BE USED AT ANY ONE TIME).
The CE-0027A will respond automatically to whichever input is used as long as the connector is properly wired.
The INPUT MODE indicator will indicate which mode is in use.
RS232 INPUT on DB25M
|
3 |
RxData |
17 |
RxClock |
|
12 |
RS232 Enable link <--------> |
24 |
RS232 Enable link |
|
7 |
Signal ground |
1 |
Protective Ground |
RS422 INPUT on DB25M
|
3 |
RxData A |
16 |
RxData B |
|
17 |
RxClock A |
9 |
RxClock B |
| 11 |
Enable link <-------------> |
23 |
Enable link |
|
7 |
Signal Ground |
1 |
Protective Ground |
RS422 output data and clock signals are available at each of the eight rear panel DB25F connectors.
RS422 OUTPUT on DB25F
|
3 |
TxData A |
16 |
TxData B |
|
17 |
TxClock A |
9 |
TxClock B |
|
7 |
Signal ground |
1 |
Protective ground |
The input port either from the RS-232 or RS-422 connector can be monitored via a front panel DB25F connector which is configured as an RS-232 DCE device and is available to monitor TxData and TxClock signals
MONITOR PORT PINOUT
|
3 |
TxData | 17 |
TxClock |
|
7 |
Signal Ground |
1 |
Protective Ground |

MODE
The RS232 or RS422 input mode LED will indicate which input connector is plugged in. This connector must be linked correctly.
OUTPUTS
Green LEDs are used to indicate the data and clock signals. The output signal itself is read and buffered so that line faults such as shorts can be detected.
POWER
This LED indicates that the internal regulated 5V supply is operating.
64Kbps maximum for both RS232 and RS422 Inputs
Nominal 240VAC 50/60Hz @ 65ma maximum
Operating temperature range 0 to 70 degrees C.
Width 484 mm
Depth 300mm
Height 88mm
Approximately 2.65 Kgs
A Maintenance Manual is provided with each unit that has following details:
1. Technical Description
2. Circuit Diagrams
3. Parts Listing
4. Certificate of Conformance
The CE-0027A conforms to the following Standards:
AS/NZS 3260:1993 (including amendments 1,2,3,4)
AS/NZS CISPR 22:2006
EIA 232C
EIA 422A